Technical data:
- Max. lamp voltage: 95V
- Max. lamp power: 75W/150W
- Ignition voltage: >25kV at 70W or >35kV at 150W
Characteristics:- Frequency range: 48 - 52Hz
- Mains voltage: 230V for HQI-TS-Lamps
- Ambient temperature: 0°C ...90°C
- Humidity class: G acc. to DIN 40040
Lamps for Ignitor voltage> 25kV:
Lamps for Ignitor voltage > 35kV:Operating mode of the temperature-monitor:The lamp stays on with the response. The electronics is switched off and admits a renewed ignition only if a switch-differential of approximately 40°C is reached. A second temperature protection guarantees that with many ignitions in quick succession the ignition voltage generation is prevented. The device becomes active only after longer pause again.
Please find the
technical drawing in the adjacent
information box!